of Carbon Silicon Analyser :-
| DEDICATED | MODEL1 | MODEL2 | MODEL3 | STEEL | |||||||||||||||||||||||||||||||||||||||||||||||||
Accuracy |
|
|
|
|
|
||||||||||||||||||||||||||||||||||||||||||||||||
Recommended Use |
C.I |
C.I | C.I/S.G/M.C.I | C.I/S.G/M.C.I | Steel C.I/S.G/M.C.I | ||||||||||||||||||||||||||||||||||||||||||||||||
Temp Measurements With Tips |
__ | __ | Provided | Provided | Provided | ||||||||||||||||||||||||||||||||||||||||||||||||
Number Of Channels |
1 | 2 | 3 | 3 | 3 | ||||||||||||||||||||||||||||||||||||||||||||||||
| Graphical PC Interface | __ | __ | __ | Provided | __ | ||||||||||||||||||||||||||||||||||||||||||||||||
| Data Transfer to Computers | __ | __ | Optional | Provided | Optional | ||||||||||||||||||||||||||||||||||||||||||||||||
| 4" Jumbo Display | __ | __ | Optional | Optional | Optional | ||||||||||||||||||||||||||||||||||||||||||||||||
| Processing Time | 2 to 3 Minutes | 2 to 3 Minutes | 2 to 3 Minutes | 2 to 3 Minutes | 30 Sec. for Steel 2 to 3 Minutes for CI/SG/MCI | ||||||||||||||||||||||||||||||||||||||||||||||||
| Printing | __ | Parallel Port | Serial & Parallel Port | Serial & Parallel Port | Serial & Parallel Port | ||||||||||||||||||||||||||||||||||||||||||||||||
| Operating Range | -20 to +55 °C | -20 to +55 °C | -20 to +55 °C | -20 to +55 °C | -20 to +55 °C | ||||||||||||||||||||||||||||||||||||||||||||||||
| Voltage | 200 to 260 V | 200 to 260 V | 200 to 260 V | 200 to 260 V | 200 to 260 V | ||||||||||||||||||||||||||||||||||||||||||||||||
| Frequency | 50 / 60 Hz, ± 2% | 50 / 60 Hz, ± 2% | 50 / 60 Hz, ± 2% | 50 / 60 Hz, ± 2% | 50 / 60 Hz, ± 2% | ||||||||||||||||||||||||||||||||||||||||||||||||
| Display | 25mm LED Hi Glow Type | 25mm LED Hi Glow Type | 25mm LED Hi Glow Type | 25mm LED Hi Glow Type | 25mm LED Hi Glow Type | ||||||||||||||||||||||||||||||||||||||||||||||||
| Memory | 32 Readings | 32 Readings | 32 Readings | 32 Readings | 32 Readings |
| DEDICATED MODEL | This is the basic model of Carbon Silicon Analyser. It has one channel to test Chemical Composition. This is best suited for oil fired crucible furnaces and cupolas where only one grade of Cast Iron is produced. This equipment can be upgraded to Model I. |
| MODEL 1 | This
equipment offers Chemical Analysis of Molten Metal. This equipment has two
selectable channels and two varieties of Cast Iron can be tested on the
equipment. This is suitable for Rotary
Furnace and Cupolas. It enables :
|
| MODEL2 | This
Model is used for Chemical Analysis & Temperature readings of molten metal
baths. It is best suited for Induction Furnaces, Cupolas and Rotary Furnaces. It offers :
Salient Features : This equipment has total 3 inputs. Two inputs for cups to measure composition and one input for molten metal temperature measurement. With this two stands of cups and one lance for tips can be connected to the instrument simultaneously. Optiomal Features :
|
| MODEL3 | Model
3 offers latest technology for Chemical & Thermal Analysis. It provides :
Salient Features: This equipment is an upgradation of Model II. The instrument has total 3 inputs. Two inputs for simultaneous scanning of the Carbon Cups. Third input is for Peak Temperature measurement using Pt-PtRh Thermocouple tips. With the treated cups, along with the liquidus and solidus temperatures, the chemical composition ( % CE, %C & %Si ) is displayed. The extent of undercooling will be measured with the help of untreated cup simultaneously. Minimum 30 readings will remain in the memory of the Carbon Silicon Analyser. This memory can be extended to 1000 nos. optionally. Computer interface is provided alongwith the instrument. The stored data is automatically copied from the instrument to the computer. A "text" file is generated in the computer. This file can be opened in Excel to handle the data as per requirement. The data is stored as graphs of cooling curves as well. The data bank generated especially for the degree of undercooling and mechanical properties, is used in predicting the properties of the future melts, such as micro-structure, micro-shrinkage etc. Other parameters like Cooling Rate, Area Of Under Cooling, Shrinkage Areas, Inoculation Levels etc. can be obtained by using this equipment. The graphs could be super imposed with a " Good Curve "and deviations in the current batch could be located. Optiomal Features :
|
| STEEL | This
Model is used for Chemical Analysis & Temperature readings of molten metal
baths. It is best suited for Induction Furnaces. It offers :
|
|| Contact Us ||
@ Suyash Enterprises
Address :
Administrative Office:
Shop No 6&7, Prayatnyasheel 'B',
Survey No 678/2, Bibwewadi.
Pune 411037. India.Tel: +91-20-24216485,24216796
Fax : +91-20-24210875
Email : se@vsnl.com